2018 GMC Yukon XL
Mileage
131,864
Service Date
9/23/2026
Services Performed
- FUSE BOX – Remove & Replace – Under Hood – [NOTE: Labor estimates listed are for R&R only and DOES NOT include diagnosis time.]
- Hook-up diagnostic scanner test equipment to perform OBD II communications test. Retrieve trouble fault code #P129D, P2535, C025E, and B3006 indicating faults for open/shorted circuits for ignition on/off, brake booster vacuum sensor, and hood ajar switch. Perform live data checks of systems voltages and sensor operations. Test for voltage at starter signal wire when attempting to start. 12V present at signal wire each time engine start is commanded. Ignition on and starter relay power present on diagnostic scanner when attempt to start. Removed fuse panel cover underhood and found fuse block slightly loose due to worn locking arms. Fuse block is removable unit that includes all relays and fuses and locking arms. Recommend replacement of underhood fuse block and quote estimate of repairs to customer. if starting issues persists, further diagnosis will be needed while vehicle is in a no-start condition.
Lurleen W. gave our service a 5 star review on 10/9/2026